zcM1000 Cutting Head Connector Replacement
Removing Old Connector:
- Remove Cutting Head and Pressure Knob from machine
- Remove 4 of each Screw from Cover and lift Cover off machine.
- Locate P200 Connector and unplug from Main Board.
- Remove Connector by unscrewing nut on inside of Cover and pulling Connector out through front on
machine.
Setting New Connector:
- Remove nut from P200-1 Connector and slide wires through Cover.
- Slide nut onto wires and attach P200-1 Connector to Cover.
- Plug Connector into Main Board.
- Replace Cover and screws.
- Replace Pressure Knob and Cutting Head.