No Power:

  • Make sure unit is plugged in
  • Turn power switch on
  • Check fuse (48)
  • Make sure Safety Cover (14) is fully closed

 

Tape not sticking to carousel:

  • Wipe down Carousel (1) with IPA
  • Tighten screw on Lever (46) to increase length of tape placed on carousel
  • Loosen screw on Arm Frame (42) to increase hold down pressure on tape

 

Won’t cut:

  • Clean blades (21/25) using IPA or equivalent
  • Inspect blades for nicks and/or wear, replace as needed
  • Using the two adjustment screws behind the upper blade, adjust blade inward by alternately tightening the two screws

 

Won’t feed / Tape jam:

  • Check upper and lower blade spacing to ensure the blades do not overlap and jam
  • Clean Tape Bite (29) with IPA
  • Clean Upper Blade (25) and Lower Blade (21) with IPA

 

Hand crank not working:

  • Remove body (11)
  • Remove Gear Cover (62)
  • Check spring on Lever (68)

 