TDA025 Turntable Replacement

 

 

TDA025 Turn Table Replacement

  1. Turn unit over and remove 4 screws that hold the top to the base.
  2. Using hand crank, cycle cutter arm until it is away from the turntable. (Make sure that
    the length adjustment is all the way back.)
  3. Remove top from base by pressing down on the tape holder arm and pushing up at an
    angle under the turntable directly across from the tape holder arm.
  4. Look into the top and remove screw and lever #7,8,9. (Be careful not to lose spring.)
  5. Remove #2 screw from inside machine, it will allow the #2 knob to be removed.
  6. Look at the turntable. Remove two screws #10.
  7. Part #3 is hooked onto #1 at two places. Using flathead screwdriver, pop #3off of #1.
    (When it is popped off, #3-6 will be loose.)
  8. Remove #1 and replace it with new turntable.
  9. Pop #3 back into #1 with parts arranged as shown. (Make sure that the slotted
    extension on #3 is opposite of the on/off switch.)
  10. Reinsert screws #10 and #2 and replace #7 lever.
  11. Replace top on machine. Use caution not to bend fan blades. Also, the slot on #3 must
    be aligned to fit over the spring-loaded arm that is attached to the turntable
    adjustment knob.
  12. Replace 4 screws that hold top onto base.